Structured Cabling

Total number of cores = 12 OR 8

Excel Category 5E Cable U/UTP Dca LS0H 305m Box - Violet

Part Code: 100-066 Key Features
  • Category: 5E
  • Overall Screening: None
  • Conductor Screening: None
  • Outer Sheath Colour: Violet
  • Reaction-to-fire Class According To EN 13501-6: Dca
  • Smoke Development Class According To EN 13501-6: S2

Excel Category 6 Cable U/UTP Dca LS0H 305m Box - Violet

Part Code: 100-071 Key Features
  • Category: 6
  • Overall Screening: None
  • Conductor Screening: None
  • Outer Sheath Colour: Violet
  • Reaction-to-fire Class According To EN 13501-6: Dca
  • Smoke Development Class According To EN 13501-6: S2

Excel Category 6 Cable U/UTP 24AWG Dca LS0H 305m Box - Violet

Part Code: 100-080 Key Features
  • Category: 6
  • Overall Screening: None
  • Conductor Screening: None
  • Outer Sheath Colour: Violet
  • Reaction-to-fire Class According To EN 13501-6: Dca
  • Smoke Development Class According To EN 13501-6: S2

Excel Category 5E Cable U/UTP External Grade Fca PE 305m Box - Black

Part Code: 100-090 Key Features
  • Category: 5E
  • Overall Screening: None
  • Conductor Screening: None
  • Outer Sheath Colour: Black
  • Reaction-to-fire Class According To EN 13501-6: Fca
  • AWG-size: 24

Excel Category 6 Cable U/UTP External Grade Fca PE 305m Box - Black

Part Code: 100-100 Key Features
  • Category: 6
  • Overall Screening: None
  • Conductor Screening: None
  • Outer Sheath Colour: Black
  • Reaction-to-fire Class According To EN 13501-6: Fca
  • AWG-size: 23

Excel Category 6 Cable U/UTP 23AWG B2ca LS0H 305m Box - Violet

Part Code: 190-071 Key Features
  • Category: 6
  • Overall Screening: None
  • Conductor Screening: None
  • Outer Sheath Colour: Violet
  • Reaction-to-fire Class According To EN 13501-6: B2ca
  • Smoke Development Class According To EN 13501-6: S1a

Excel Category 6A Cable U/FTP S-Foil Dca LS0H 305m Box - Ice Blue

Part Code: 100-191-305M Key Features
  • Category: 6A (IEC)
  • Overall Screening: None
  • Conductor Screening: Foil
  • Outer Sheath Colour: Ice Blue
  • Reaction-to-fire Class According To EN 13501-6: Dca
  • Smoke Development Class According To EN 13501-6: S2

Excel Category 5E Cable U/UTP Eca PVC 305m Box - Grey

Part Code: 100-065 Key Features
  • Category: 5E
  • Overall Screening: None
  • Conductor Screening: None
  • Outer Sheath Colour: Grey
  • Reaction-to-fire Class According To EN 13501-6: Eca
  • AWG-size: 24

Excel Category 6A Cable U/FTP S-Foil Cca LS0H 305m Box - Ice Blue

Part Code: 170-191-305M Key Features
  • Category: 6A (IEC)
  • Overall Screening: None
  • Conductor Screening: Foil
  • Outer Sheath Colour: Ice Blue
  • Reaction-to-fire Class According To EN 13501-6: Cca
  • Smoke Development Class According To EN 13501-6: S1a

Excel Category 5E Cable U/UTP Dca LS0H 305m Box - White

Part Code: 100-060 Key Features
  • Category: 5E
  • Overall Screening: None
  • Conductor Screening: None
  • Outer Sheath Colour: White
  • Reaction-to-fire Class According To EN 13501-6: Dca
  • Smoke Development Class According To EN 13501-6: S2